| Tensile Strength (UTS) | 1100–1300 MPaRoom temp, longitudinal, d ≤16 mmEN 10083-3 +QT | 655 MPatypicalRoom temp, longitudinalTypical — not specified | 1020 MPatypicalRoom temp, longitudinal, ~25 mm sectionTypical — not specified [VERIFY — handbook typical value] | 862 MPaminTypical 950 MPaRoom temp, longitudinal, T/4 or mid-radius125 ksi min (purchase-spec minimum) [VERIFY vs customer spec] | 655 MPaminTypical 760 MPaRoom temp, longitudinal, T/4 or mid-radius95 ksi min (purchase-spec minimum); typical value indicative |
|---|
| Tensile Strength (UTS) | 1000–1200 MPaRoom temp, longitudinal, 16 < d ≤ 40 mmEN 10083-3 +QT | – | – | – | – |
|---|
| Tensile Strength (UTS) | 900–1100 MPaRoom temp, longitudinal, 40 < d ≤ 100 mmEN 10083-3 +QT — website headline band | – | – | – | – |
|---|
| Tensile Strength (UTS) | 800–950 MPaRoom temp, longitudinal, 100 < d ≤ 160 mmEN 10083-3 +QT | – | – | – | – |
|---|
| Tensile Strength (UTS) | 750–900 MPaRoom temp, longitudinal, 160 < d ≤ 250 mmEN 10083-3 +QT | – | – | – | – |
|---|
| Tensile Strength (UTS) | 850–1000 MPaRoom temp, longitudinal, BS 970 709M40 Condition TEN19T — within limiting ruling section | – | – | – | – |
|---|
| Yield Strength (0.2% Proof Stress) | 900 MPaminRoom temp, longitudinal, d ≤16 mmEN 10083-3 +QT | 415 MPatypicalRoom temp, longitudinalTypical — not specified | 655 MPatypicalRoom temp, longitudinal, ~25 mm sectionTypical — not specified [VERIFY — handbook typical value] | 758 MPaminTypical 820 MPaRoom temp, longitudinal, T/4 or mid-radius110 ksi min | 552 MPaminTypical 620 MPaRoom temp, longitudinal, T/4 or mid-radius80 ksi min; exceeds API 6A 75K (517 MPa) |
|---|
| Yield Strength (0.2% Proof Stress) | 750 MPaminRoom temp, longitudinal, 16 < d ≤ 40 mmEN 10083-3 +QT | – | – | – | – |
|---|
| Yield Strength (0.2% Proof Stress) | 650 MPaminRoom temp, longitudinal, 40 < d ≤ 100 mmEN 10083-3 +QT | – | – | – | – |
|---|
| Yield Strength (0.2% Proof Stress) | 550 MPaminRoom temp, longitudinal, 100 < d ≤ 160 mmEN 10083-3 +QT | – | – | – | – |
|---|
| Yield Strength (0.2% Proof Stress) | 500 MPaminRoom temp, longitudinal, 160 < d ≤ 250 mmEN 10083-3 +QT | – | – | – | – |
|---|
| Yield Strength (0.2% Proof Stress) | 680 MPaminRoom temp, longitudinal, BS 970 709M40 Condition TEN19T [VERIFY — published stockist values range 650–680 MPa] | – | – | – | – |
|---|
| Elongation | 12 %minA5 (5.65√S0), 40 < d ≤ 100 mmEN 10083-3: 10 / 11 / 12 / 13 / 14% min for the five bands ≤16 to 250 mm | 25 %typical50 mm gauge lengthTypical — not specified | 17.7 %typical50 mm gauge lengthTypical — not specified [VERIFY — handbook typical value] | 15 %minTypical 18 %50 mm gauge lengthPurchase-spec minimum [VERIFY vs customer spec] | 18 %minTypical 22 %50 mm gauge lengthPurchase-spec minimum; API 6A 75K requires 17% [VERIFY vs customer spec] |
|---|
| Elongation | 13 %minBS 970 709M40 Condition TEN19T | – | – | – | – |
|---|
| Reduction of Area | 50 %minRoom temp, longitudinal, 40 < d ≤ 100 mmEN 10083-3: 40 / 45 / 50 / 50 / 55% min for the five bands | 56 %typicalLongitudinalTypical — not specified | 46.8 %typicalLongitudinalTypical — not specified [VERIFY — handbook typical value] | 45 %minTypical 55 %LongitudinalPurchase-spec minimum [VERIFY vs customer spec] | 35 %minTypical 55 %LongitudinalAPI 6A 75K minimum; typical value indicative |
|---|
| Impact Energy (Charpy) | 35 JminKV, +20°C, 16 < d ≤ 250 mmEN 10083-3: 30 J min for d ≤16 mm | – | – | –V-notch, per ordered temperaturePer customer spec (commonly −20°C) [VERIFY — enter value when PO specifies] | –V-notch, per ordered temperature classPer customer spec / API 6A temperature class (typically −29°C or −46°C) [VERIFY — enter value when PO specifies] |
|---|
| Impact Energy (Charpy) | 50 JminKCV / Izod, BS 970 709M40 Condition TEN19T [VERIFY — source not confirmed against BS 970-1] | – | – | – | – |
|---|
| Hardness | 271–331 HBtypical40 < d ≤ 100 mmInformative only in EN 10083-3 (not a specified requirement) | 241 HBmaxTypical 197 HBSurfaceEN 10083-3 +A max (specified); 197 HB typical full anneal | 302 HBtypicalSurface, ~25 mm sectionTypical; heavier sections ~270 HB | 285–341 HBTypical 311 HBSurface and section survey≈30–36 HRC. Not sour-service compliant | 22 HRCmaxTypical 20 HRCSurface and section surveyNACE MR0175 / ISO 15156-2 maximum; ≤237 HBW |
|---|
| Hardness | 248–302 HBSurface, BS 970 709M40 Condition TEN19T specified hardness range | – | – | – | – |
|---|